logo

Jeol 2010f instruction manual


Or its subsidiary company responsible for thsubject ( hereinafter referred to as e JEOL RESONA" ) : modifying the NCE" instrument;. JEM 2100F TEM Daily Operation Guide. Choose Signal: Click the active data display [ Signal], double- click to select [ SEI] ( second. J2100F Daily Operation Guide Last modified on Nov.


Find here all the necessary documents and downloads that you may be interested for the JEOL instrument that you are using. The JEM- 2100F is a multipurpose, 200 kV FE ( Field Emission) analytical electron microscope. Glow Engine The Sport is suited for a. LOG IN to your session on the computer to the left of the microscope. The information contained in this manual is subject to change without notice.

If the SEM software is not running, start SEM Software ( SEM Main Menu icon). Verify the vacuum in JEOL PC / TEMCON / Valve Status window VACUUM SYSTEM GUN/ CAMERA valves • V1 and V2 = OFF ( black) Pirani gauge status • PIG- 2 < 30 µA • PIG- 1 < 30 µA. Check System: Pumps running and EVAC light green ( main panel near key switch)?

JEM- 2100 Instructions v 1. Core product groups include electron microscopes ( SEMs and TEMs), instruments for the semiconductor industry ( electron beam lithography and a series of defect review and inspection tools) and analytical instruments including mass spectrometers, NMRs and ESRs. JEOL, JEM- Handbook- Basic Operation ( Second Edition) Contents Chapter ( page) Title 1 ( 2) Guidelines 2 ( 3) Sample Insertion and Filament Procedure 3 ( 6) How to find beam ( short formBasic operating: DIFF, BF, DF, Photo, CBD, NBD and EDSChanging specimen or ending sessionMore detailed instruction. The settings can be modified to produce the best images of your samples. NanoScale Fabrication and Characterization Facility, University of Pittsburgh. 0 Note: This is minimal operation checklist and does not replace the other reference manuals.

Please remember that the following should be used only as a starting point for your particular work. Manufacturer Specifications - F, Jeol Please note: None of the equipment posted for sale on MedWOW. JEOL’ sunique stigma memory automatically corrects astigmatism caused by a change of accelerating voltage or working distance. ( Use keyboard and mouse lying on top of Gatan computer to log into that computer. JEOL 7000F BASIC OPERATING INSTRUCTIONS- Ver. This manual is not intended to be formal.


With the instruction manual, may cause harmful interference to the environment, especially radio communications. Launch the Client ( username = user, password = jem- f). ) After this, the computers should be controllable by JEOL mouse and keyboard.
This is 10 times larger than that obtained with a conventional design. Check the accelerating voltage, must be at 200 kV ( right screen), HT ( µA) ( left panel) at 0. JEOL 6500 User Manual. You can do much more damage to it than it can do to you. Basic operating instructions.

Starting Session 1. The first option is to just search “ [ Device Name] Instruction Manual”. In this document, we will always refer to it as CL3, since that is the convention used by the JEOL service. 1 EM Facility CMSE- SEF Massachusetts Institution of Technology March.


View and Download Jeol JEM- 2100F instruction manual online. JEOL F MANUAL Quick check list 1. JEM- 2100F Microscope pdf manual download. The JSM- 7001F with the in- lens thermal FEG can produce a probe current larger than 200 nA at 15 kV. 97 and Emission ( left panel) at. If the HT is not at 200 kV, use the FasTEM Client to increase it.

Search engines will do a lot better job of combing through the depths of of a manufacturer’ s site than you. 14, Note: This guide is NOT complete operation manual of J2100F. , Pittsburgh, PA 15261. Field emission electron microscope. These are the only procedures you should carry out, unless you have received specific additional training.
• The following actions must be avoided without prior written permission from JEOL RESONANCE Inc. If the instruction manuals section isn’ t immediately apparent on the website, it’ s time to turn to a web search. The electron microscopy facility is a multidisciplinary research and educational core facility within the College of Science at Northeastern University.

This document is an introduction to the operation of the JEOL 5800LV scanning electron microscope and the Oxford Isis 300 analytical system. When the server GUI minimizes, restore it and enter a password ( jem- f). 4mm] R/ C foam rubber ( HCAQ1000).
It makes selection. If not notify a staff member. TEM Operation Manual. Currently it maintains three electron microscopes including high- resolution transmission electron microscope ( TEM) JEOL F, high- contrast TEM JEOL JEM- 1010, and high- resolution field emission scanning electron microscope ( SEM) Hitachi S- 4800. The following procedure is a general operating procedure that the majority of users will apply when working on the JEOL TEM. This manual contains information regarding the basic operation of this microscope for conventional imaging.

They inconsistently refer to the second condenser lens as CL3, the third condenser lens, or CL2. When the electron beam is turned on, some x- rays are. JEOL JSM- 6480 SEM Instruction Manual 4 ─ Prepared by Haitao Zhang, revised May decrease the aperture, pull the knob outward and then rotate it counterclockwise to stop and then release it. Read the manual for Specimen Exchange ( JEOL 7000 Specimen Exchange INSTRUCTIONS) before you read this manual. Safety The scanning electron microscope is a relatively safe instrument.

JEOL JEM TRAINING TRANSMISSION ELECTRON MICROSCOPE USER MANUAL Version 5. Jeol 2010f instruction manual. JEOL JSM- 6060LV scanning electron microscope is user- friendly and easy to operate. JEOL 1200- EX II TEM TEM Components/ Controls/ Functions Table 2 Routine Alignment and Operation for the Independent User Starting Conditions 4 High Voltage Generation and Conditioning 4 Electron Beam Generation – Preliminary 4 Gun Alignment 5 Condenser Lens Alignment 5 Condenser 2 Stigmation 5. Recommended in the instruction manual, be certain the servos do not overload the BEC or voltage regulator. Jeol JEM- 2100F Pdf User Manuals. Spilde & Jana Berlin April Update: December University of New Mexico Department of Earth and Planetary Science. A beam of electrons hitting a thin sample will be transmitted and scattered at different. JEOL is a world leader in electron optical equipment and instrumentation for high- end scientific and industrial research and development.

JEOL USA Electron Optics Documents. If not, launch the Server. Verify the vacuum: If vacuum is not good enough, contact somebody from the LME staff.
Com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page. Holding the rod horizontally, rotate both ways about its access and jiggle the -. This manual should be considered a work in progress. Click yes if message on screen about stage appears. Page 3 of 13 Introduction The fundamental basis of electron microscopy is the interaction of electrons with matter. The camera' s control system is fully integrated into the TEM control system, TEM Center, for simple, intuitive operation.

Ensure that on the JEOL computer FasTEM Server and FasTEM Client are running. And any of our affiliates have concluded no agency relationship and no contractual relationship with Ervin Danesh Aryan Company in Islamic Republic of Iran on our manufactures and sell, services and any others in all cases in the past and current business. All holders: Lift the holder with two hands, touching only the handle, or the portion of the rod between the handle and orings. It takes several minutes to start, be patient. Office: B1 Benedum Hall, 3700 O’ Hara St.

Table shows JEOL recommended values. JEOL JXA- 8200 SUPERPROBE OPERATOR' S MANUAL Michael N. On Demand Tankless Series Model Spec Sheet On Demand Indoor Outdoor 110 AOSRGAOSRGAOSBGIndoor AOSRGOutdoor AOSRGAOSCGAOSCG14001 On Demand Indoor Outdoor200 SeriesAOSRG46800No Longer in< / p>. This happened because the F manual is an expanded and modified manual, resulting in several inconsistencies. Starting Conditions.


4 Fully integrated high resolution CCD camera system JEOL has developed a new 8 million pixel camera, optimized for the JEM- 1400plus. JEM 2100 Manual Operation and Basic Alignment Instructions 1. It is only for your daily operation quick reference. Other Accessories for a Glow Engine 1/ 4" [ 6.

BASIC Step- by- Step Instructions for JEOL 6060LV Version 4/ 13/ 11 General Operation 1. Button and read the Penning Gauge to ensure that the. View online or download Jeol JEM- 2100F Instruction Manual. Jeol 2010f instruction manual. We need to be very careful with some types of specimens.

Follow the procedures below when you use the JEM1400- Plus TEM. With time, we will add sections as operating procedures are developed or improved by user experience. Press Ctrl- Alt- Del and log on to the microscope computer.

Express ourselves that we as JEOL Ltd. Auto- bias by JEOL sets the optimum brightness over the entire range of the accelerating voltage from the lowest voltage to the highest voltage, with the possibility of manual override. If not logged in, log in to the " user" accounts on the JEOL and Gatan computers. Please send me a copy of your publication ( e- format preferred) if you have TEM results taken with this microscope. Variety of versions is provided to adapt user’ s purposes.

JEOL JEM- 1230 Operating Instructions. The in- lens thermal FEG is a combination of a Schottky FEG and the low- aberration condenser lens, and is designed to collect electrons from the gun efficiently. Click on JEOL PC SEM 6500 icon. 46AXII ( OSMG0548) is illustrated in this manual. Switching on the beam Switch on the beam by selecting “ on” at the top of the left menu window.